MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Structural Design Error Cases › Drop Impact During Lifting
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Drop Impact During Lifting Causes Brittle Fracture of the Cast Iron Frame

E42-131 · Impact & Overload Fracture · Conveyor Cast Iron Frame · ★★

Problem Symptom

During lifting the frame was dropped and the foot region fractured brittlely

Root Cause

[Impact Load] The drop gives an impact acceleration a=20g, and the momentum produces an instantaneous impact P=m·a far above the static strength.
[Brittle Fracture] Cast iron is notch sensitive with low impact toughness, so it fractures at the stress concentration at the foot.
[Design Omission] No lifting protection was provided, the cast iron was not changed to steel and no buffering was used.

Correct Solution

1) Change the frame to welded steel to raise toughness;
2) Fit lifting protection stops;
3) Add fillets at the feet to reduce the stress concentration;
4) Check the drop impact by simulation;
5) Arrange the lifting points about the center of gravity;
6) Add buffering pads during transport;
7) Inspect on arrival for appearance and by UT;
8) Include the lifting impact in the transport specification.

Checklist

References

GB/T 3766 Hydraulic Transmission Systems — General Technical Conditions

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL