E42-133 · Impact & Overload Fracture · Automated High Bay Warehouse Stacker · ★★
The shifted load struck the mast and the H-section steel bent plastically
[Impact Load] The shifted fork struck the column, and the impact force F gives a bending moment M=F·h that exceeds the yield strength.
[Plastic Bending] The H-section yields locally and bends plastically with no recovery.
[Design Omission] No anti-collision guard rail and no travel limit were provided.
1) Add anti-collision guard rails in the aisle;
2) Add a shift detection limit on the fork;
3) Check the mast against the impact by finite element;
4) Add reinforcing plates to the mast flanges;
5) Straighten or replace the mast;
6) Add an anti-collision alarm interlock;
7) Limit the travel speed;
8) Include the impact load in the design.
JB/T 7016 Rail-mounted Stacking Cranes