E42-531 · Impact and Overload Fracture · Die Forging Hammer (1t) · ★★★
Ram guide rod φ120; over-strike overload σ=650MPa exceeds allowable 450; fractured; 1 rod scrapped per month
[Overload] σ=650> allowable 450; fractured after plastic deformation.
[Impact] Instantaneous load.
[Design Omission] No limit, no calculation; safety factor 1.0 (should be ≥1.5).
1) Provide an overload limit;
2) Raise guide rod strength;
3) Limit blow energy;
4) Check the rod each shift;
5) Limit tonnage;
6) Flaw inspection;
7) Preheat;
8) Periodic re-measurement.
GB/T 13421-2012