E42-498 · Impact and Overload Fracture · Coupling Safety Pin · ★★
Coupling safety pin (φ12) sheared under overload; drive broken; replaced 3 times per month
[Shear] Peak torque T=8kN·m exceeded the pin shear strength and fractured it.
[Fracture] Drive lost.
[Design Omission] Shear not verified, no cushioning; safety factor 1.3 (should be ≥2.0).
1) Re-calculate safety pin shear;
2) Provide a torque limiter;
3) Add elastic cushioning;
4) Limit peak torque;
5) Check the pin each shift;
6) Line the pin slot;
7) Upgrade material to 45 steel;
8) Periodic re-measurement.
GB/T 4323-2002