Wrong Clearance Fit Causes the Bearing Outer Ring to Creep in the Housing

E42-035 · Fit & Interference Failures · Motor End Cover Bearing Bore · ★★★

Problem Symptom

The bearing outer ring rotated in the housing bore and wore

Root Cause

[Loose Fit] The selected H7/g6 clearance fit gives 0.02 of clearance, so the ring creeps slightly during running.
[Wear] The creep grinds out 0.1 of clearance, producing abnormal noise and heat generation.
[Design Omission] A small interference H7/k6 should have been used; the wrong fit was chosen and wear resulted.

Correct Solution

1) Change to a small interference H7/k6 fit;
2) Specify housing bore roughness Ra1.6;
3) Apply anaerobic adhesive;
4) Select the fit according to the rotational speed;
5) Press-fit the bearing;
6) Monitor for abnormal noise;
7) Replace the damaged bearing;
8) Include bearing fit selection in motor end cover design.

Checklist

References

GB/T 275 Bearing Fits