Form and Position Tolerance Overshoot Causes Assembly Binding

E42-036 · Fit & Interference Failures · Plunger in Cylinder Block · ★★★

Problem Symptom

After assembly the plunger seized and could not be withdrawn

Root Cause

[Coaxiality] The bore-to-shaft coaxiality exceeds 0.05 and the one-sided clearance is 0.02, giving an interference of 0.03.
[Binding] The 0.03 interference locks the plunger after assembly so it cannot slide.
[Design Omission] No form and position tolerance was specified and none was inspected, so binding occurred.

Correct Solution

1) Specify coaxiality ≤0.01;
2) Raise the diameter accuracy to IT6;
3) Lap and hand-fit the parts;
4) Inspect form and position on a three-coordinate measuring machine;
5) Select parts by clearance;
6) Carry out an assembly sliding test;
7) Leave grinding allowance for finish machining;
8) Make form and position tolerances a mandatory callout on assembly drawings.