E42-184 · Fit and Interference Failure · Fan Impeller Journal · ★★
Journal-to-bushing clearance 0.3mm (allowable 0.05); loose rotation and noise.
[Excessive Clearance] Wrong fit H7/e9 selected; operating wear expanded clearance to 0.3mm. [Loose Rotation] Journal eccentric wear, vibration and noise. [Design Omission] Did not select H7/f6, no replaceable bushing; vibration exceeded limits.
1. Change the fit to H7/f6 or H7/h6.
2. Provide a replaceable bushing for easy maintenance.
3. Add keys to the bushing inner/outer circles to prevent rotation.
4. Surface-harden the journal to improve wear resistance.
5. Measure clearance periodically.
6. Select lubrication for boundary lubrication.
7. Dynamically balance the impeller.
8. Replace the bushing when clearance is exceeded.
GB/T 1800.2-2009