E42-308 · Fit and Interference Failure · Shrink-Fit Gear · ★★★
Gear (Φ200) bore cracked circumferentially after shrink-fitting (300℃); 2 parts scrapped per month
[Thermal Stress] Uneven heating; bore locally 300℃, outer edge 80℃; thermal stress σ=350MPa exceeds strength.
[Crack] Thermal stress caused circumferential bore crack 40mm long.
[Design Omission] No uniform heating, no temperature control; safety factor only 1.1.
1) Induction heat uniformly, control to 250℃;
2) Preheat the whole part to 100℃ before heating;
3) Add an anti-crack ring to the bore;
4) Cool at a uniform rate to prevent quenching;
5) UT inspect each part;
6) Temperature field simulation;
7) Post-assembly inspection;
8) Process qualification.
GB/T 8539-2008