E42-307 · Fit and Interference Failure · Gearbox Bearing Housing · ★★
Gearbox bearing housing bore (Φ120) worn loose; bearing outer ring rotated; 3 units repaired per month
[Micro-Rotation Wear] Insufficient interference plus vibration; outer ring micro-rotated and wore 0.05mm.
[Loosening Enlargement] Bore measured Φ120.1; clearance out of tolerance.
[Design Omission] Interference not controlled, no monitoring; safety factor only 1.2.
1) Line the housing bore with a steel sleeve to restore interference;
2) Raise interference by 0.03mm;
3) Quench the bore surface to HRC40;
4) Add an axial retaining ring;
5) Measure bore diameter each batch;
6) Online vibration monitoring;
7) Prohibit hammer assembly;
8) Periodic re-measurement.
GB/T 307.1-2017