Knowledge Base › Structural Design Error Case Study › Pulley Hub Insufficient Interference Causing Loose Rotation and Sheared Key

Pulley Hub Insufficient Interference Causing Loose Rotation and Sheared Key

E42-306 · Fit and Interference Failure · Motor Pulley Hub · ★★

Problem Description

Motor pulley (Φ80) interference fit to shaft rotated loose; key sheared; 4 shutdowns per month

Root Cause

[Insufficient Interference] Interference δ=0.02mm (should be ≥0.05); insufficient torque transmission.
[Micro-Rotation Wear] Actual contact pressure p=15MPa below required 20MPa; micro-rotation wore the shaft.
[Design Omission] Interference not calculated, faying surface not controlled; safety factor only 1.2.

Corrective Solution

1) Raise interference to 0.05-0.08mm;
2) Grind faying surfaces to Ra0.8 and prohibit oil;
3) Add double keyways to share torque;
4) Control shrink-fit temperature to 250℃;
5) Measure interference each batch;
6) Torque transmission verification;
7) Anti-loosening marks;
8) Finalize the assembly process card.