E42-186 · Fit and Interference Failure · Conveyor Roller Track Bearing Housing · ★★
The inner ring rotated relative to the shaft; bright wear marks on the shaft.
[Wrong Tolerance] Shaft diameter taken as g6 (should be k6); interference insufficient 0.01. [Creeping] Inner ring micro-moved on the shaft surface, wearing a bright band. [Design Omission] Tolerance band not selected per bearing, no tapered adapter; premature failure.
1. Change shaft diameter tolerance band to k6.
2. Add a tapered adapter sleeve to the bearing inner ring.
3. Select interference per the bearing.
4. Use shaft shoulder for positioning against axial movement.
5. Assembly heating ≤120℃.
6. Listen during operation to detect creeping.
7. Periodically check bright bands on the shaft.
8. Analyze prematurely failed bearings.
GB/T 275-2015