E42-037 · Linear Guide Accuracy · Sliding Guide Rail Table · ★★★

Problem Symptom

Crawl marks and surface waviness at low speed

Root Cause

[Stick-Slip] At the bond line the ratio μ_s/μ_k=0.18/0.08 and the difference of 0.10 triggers stick-slip.
[Crawl] The critical speed is v_c=(μ_s-μ_k)/k≈12mm/min, so crawl marks appear at low speed.
[Design Omission] The bonding process was poor and the adhesive had not cured, so the table crawled.

Correct Solution

1) Re-bond the plastic lining and grind it;
2) Use a dedicated adhesive and cure for 24h;
3) Scrape and spot-face the surface to 12 points per 25²mm;
4) Optimise the lubrication (guide oil);
5) Carry out a low-speed crawl test with no marks at ≤5mm/min;
6) Trim the surface;
7) Standardise the bonding process;
8) Include the crawl test in guide rail acceptance.

Checklist

References

JB/T 9871 Guide Rails