Lubrication Failure on a Linear Guide Causes Brinelling and Scoring

E42-089 · Linear Guide Accuracy · Linear Guide HGH25 · ★★

Problem Symptom

Scoring of the raceways after the lubrication supply was interrupted

Root Cause

[Lubrication] The oil hole was blocked and dry metal-to-metal friction occurred.
[Scoring] Direct metal contact scored the raceways.
[Design Omission] No lubrication monitoring was provided and oil was not supplied on a schedule, so scoring occurred.

Correct Solution

1) Add oil level monitoring;
2) Provide timed automatic oil supply;
3) Clear the oil holes;
4) Test the oil quality;
5) Repair the scored surfaces;
6) Fit dust wipers;
7) Provide redundancy in the lubrication circuit;
8) Include the lubrication monitoring in the electrical control.

Checklist

References

JB/T 7175.4-2016 Linear Rolling Guide Rail Assemblies

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL