E42-448 · Guideway Alignment Accuracy · GLOBAL CMM air-bearing guide · ★★★
GLOBAL CMM air-bearing guideway (length 1200): uneven air film, each-axis drift 0.008mm over allowable 0.003, measurement inaccurate; calibrated 3 times a month
[Poor air film] Uneven air-bearing throttling, air-film thickness difference 2μm, drift. [Inaccuracy] Measurement error out of tolerance. [Design Omission] No pressure equalization, no temperature control; safety factor 1.3 (should be ≥2.0).
1) Optimize air-bearing pressure-equalizing chamber;
2) Control air-film thickness ≤3μm;
3) Ambient temperature ±1℃;
4) Calibrate each shift;
5) Clean air source;
6) Add linear encoder feedback;
7) Limit speed;
8) Periodic re-measurement.
GB/T 16857.2-2017