MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Structural Design Error Case Study › CMM Air-Bearing Guide Drift

CMM Air-Bearing Guide Drift

E42-448 · Guideway Alignment Accuracy · GLOBAL CMM air-bearing guide · ★★★

Problem Description

GLOBAL CMM air-bearing guideway (length 1200): uneven air film, each-axis drift 0.008mm over allowable 0.003, measurement inaccurate; calibrated 3 times a month

Root Cause

[Poor air film] Uneven air-bearing throttling, air-film thickness difference 2μm, drift. [Inaccuracy] Measurement error out of tolerance. [Design Omission] No pressure equalization, no temperature control; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Optimize air-bearing pressure-equalizing chamber;
2) Control air-film thickness ≤3μm;
3) Ambient temperature ±1℃;
4) Calibrate each shift;
5) Clean air source;
6) Add linear encoder feedback;
7) Limit speed;
8) Periodic re-measurement.

Checklist

Reference

GB/T 16857.2-2017

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL