E42-449 · Guideway Alignment Accuracy · MAKE4500 injection guide · ★★

Problem Description

MAKE4500 injection seat guideway parallelism 0.05mm, screw-barrel eccentricity 0.1mm over allowable 0.04, uneven plasticizing; repaired 2 times a month

Root Cause

[Parallelism error] Injection guide 0.05mm out of parallel, seat swing. [Eccentricity] Screw and barrel not coaxial. [Design Omission] No scraping, no datum; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Scrape guideway to parallel ≤0.02mm;
2) Set alignment datum;
3) Add guidance to injection seat;
4) Alignment check each shift;
5) Limit injection speed;
6) Add coaxial monitoring;
7)Preload;
8) Periodic re-measurement.