E42-481 · Guideway Alignment Accuracy · Gantry mill crossbeam guide · ★★
Gantry mill (XK2012) crossbeam guideway twist 0.03mm/m, machining flatness 0.08 out of tolerance; 3 pieces returned monthly
[Guideway twist] Crossbeam Y-guide twist 0.03mm/m caused spindle offset.
[Flatness error] Accumulated error.
[Design Omission] No scraping, no twist measurement; safety factor 1.4 (should be ≥2.0).
1) Scrape guideway to 0.01mm/m;
2) Add dual-guide twist relief;
3) Rib the crossbeam;
4) Laser twist measurement;
5) Straighten each shift;
6) Limit crossbeam extension;
7) Add counterweight;
8) Periodic re-measurement.
GB/T 23567.1-2009