E42-482 · Guideway Alignment Accuracy · Injection machine tie-bar guide · ★★
Injection machine (480t) tie-bar guide column wear 0.2mm, mold-closing offset 0.5mm flash; repaired twice a month
[Wear] Guide column PV=8MPa·m/s exceeded, wore 0.2mm.
[Offset] Mold closing inaccurate.
[Design Omission] No hardening, no lubrication; safety factor 1.4 (should be ≥2.0).
1) Quench guide column HRC55;
2) Add self-lubricating bushing;
3) Limit PV≤4;
4) Level mold closing;
5) Wear check each shift;
6) Add dust protection;
7) Upsize diameter;
8) Periodic re-measurement.
GB/T 25156-2010