Large Slenderness Ratio of the Column Causes Buckling in Compression

E42-040 · Structural Instability & Buckling · Press Column · ★★★

Problem Symptom

The eccentrically loaded column buckled and bent sideways

Root Cause

[Slenderness Ratio] With L=2000, i=40, λ=50, the Euler critical stress is σ_cr=π²E/λ²=π²×2.1e5/2500=829MPa.
[Eccentricity Reduction] The eccentricity e=20 raises the bending stress σ_m=σ+P·e·c/I, and after the reduction the allowable stress σ_allow=300 is below the working stress of 350.
[Design Omission] Stability was not calculated and no ribs were added, so the column buckled.

Correct Solution

1) Add ribs to reduce the slenderness ratio to λ=35;
2) Change to a box section to raise I;
3) Carry out a stability check with n≥2;
4) Reduce the eccentricity to e≤10;
5) Add preloading;
6) Run a finite element buckling simulation;
7) Perform flaw detection on critical columns;
8) Include stability check-up in column design review.

Checklist

References

GB/T 3811 Stability

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »