E42-041 · Structural Instability & Buckling · Vacuum Vessel Shell · ★★★

Problem Symptom

The shell collapsed inward when the vacuum was drawn

Root Cause

[External Pressure Critical Value] With D=1000, t=6 and L=2000, the critical pressure is p_cr=2E(t/D)³=2×2e5×(6/1000)³=0.086MPa.
[Instability] The 0.1MPa vacuum exceeds 0.086MPa and the shell collapses.
[Design Omission] External-pressure stability was not calculated and the wall was too thin, so the vessel collapsed inward.

Correct Solution

1) Increase the wall thickness or add circumferential stiffening ribs;
2) Carry out an external-pressure stability check;
3) Fit a safety valve;
4) Add support rings;
5) Run a simulation;
6) Carry out a vacuum trial;
7) Inspect the result;
8) Include external-pressure stability check-up in vacuum vessel design.

Checklist

References

GB/T 150 Pressure Vessels