E42-091 · Structural Instability & Buckling · Vacuum Tank Q345R · ★★★
The tank collapsed inward when the vacuum was drawn
[External Pressure Instability] The external pressure exceeded the critical value and the tank wall dented inward.
[Collapse] This is the instability deformation.
[Design Omission] External-pressure stability was not calculated and the wall thickness was insufficient, so the tank collapsed inward.
1) Check external-pressure stability with a factor of at least 2;
2) Increase the wall thickness to δ=8mm;
3) Add circumferential stiffening rings;
4) Limit the evacuation rate;
5) Monitor the vacuum level;
6) Carry out an instability test;
7) Calculate the spacing of the stiffening rings;
8) Include external-pressure stability in the design.
GB/T 150.1-2011 Pressure Vessels