Excessive Slenderness Ratio of Tower Compression Members Causes Crushing

E42-092 · Structural Instability & Buckling · Tower Structure Q355 · ★★

Problem Symptom

The compression member buckled

Root Cause

[Slenderness Ratio] λ=120 exceeds the allowable 100.
[Crushing] The member failed by unstable bending.
[Design Omission] The slenderness ratio was not controlled and stability was not calculated, so the member crushed.

Correct Solution

1) Control the slenderness ratio at ≤100;
2) Increase the section or add lacing bars;
3) Check the stability factor;
4) Improve the joint rigidity;
5) Calculate the wind load;
6) Anchor the foundation properly;
7) Monitor the deformation;
8) Make stability a mandatory calculation.

Checklist

References

GB 50017-2017 Code for Design of Steel Structures