Excessive Slenderness Ratio of a Slender Compression Member Causes Out-of-Plane Instability

E42-141 · Structural Instability & Buckling · Truss Compression Chord Member · ★★

Problem Symptom

The chord member has a large slenderness ratio and buckles out of plane in compression

Root Cause

[Compression Member Instability] For a pin-ended member the critical force is Pcr=π²EI/L², and the slenderness ratio λ=120 exceeds the limit.
[Instability] The actual load exceeds Pcr and the member buckles out of plane.
[Design Omission] The slenderness ratio was not controlled and no lateral bracing was provided.

Correct Solution

1) Reduce the slenderness ratio to λ≤100;
2) Add lateral bracing points;
3) Increase the section to raise the second moment of area;
4) Prepare a member stability calculation sheet;
5) Check the joint rigidity;
6) Measure the actual load;
7) Replace the buckled member;
8) Include stability in the truss design.

Checklist

References

GB 50017 Code for Design of Steel Structures