Unbraced Compression Flange of a Rigid Frame Causes Lateral-Torsional Instability

E42-142 · Structural Instability & Buckling · Portal Frame Cross Beam · ★★

Problem Symptom

The compression flange is unbraced out of plane and fails by lateral-torsional buckling

Root Cause

[Lateral-Torsional Buckling] The compression flange of the I-beam has no lateral restraint, so bending and torsion couple and the member becomes unstable.
[Instability] The critical bending moment is below the design value and the beam buckles laterally.
[Design Omission] No knee braces or tie rods were provided and the overall stability was not checked.

Correct Solution

1) Provide knee braces or tie rods at the compression flange;
2) Verify the overall stability factor;
3) Widen the flange of the beam section;
4) Add torsional restraint at the joints;
5) Re-check the load cases;
6) Reinforce the buckled zone;
7) Monitor the deflection;
8) Include overall stability in the rigid frame design.

Checklist

References

GB 50017 Code for Design of Steel Structures