E42-541 · Structural Instability and Buckling · Vacuum tank (φ1500) · ★★★
Wall 6mm, external-pressure instability dented and deformed; 1 unit scrapped yearly
[External-pressure buckling] p=0.1MPa, small critical pcr, dent.
[Thin wall] t=6 small.
[Design Omission] No external-pressure stability check, thin wall; safety factor 1.2 (should be ≥2.5).
1) Raise wall thickness to 10mm;
2) Add circumferential ribs;
3) Provide stiffener ring;
4) Dent check per furnace;
5) Limit vacuum;
6) Upgrade material;
7)NDE;
8) Periodic re-measurement.
GB/T 150.1-2011