Knowledge Base › Structural Design Error Case Study › Jib Compression Buckling

Jib Compression Buckling

E42-542 · Structural Instability and Buckling · Crane jib · ★★★

Problem Description

Jib φ140×8: compression buckled, arm sagged, lifting load reduced; repaired once a year

Root Cause

[Compression buckling] λ=95, Pcr insufficient, arm sagged.
[Eccentricity] Load offset.
[Design Omission] No column stability check, small section; safety factor 1.2 (should be ≥2.5).

Corrective Solution

1) Upsize jib;
2) Reduce slenderness;
3) Provide tie rod;
4) Sag check each shift;
5) Limit lifting load;
6) Upgrade material;
7)NDE;
8) Periodic re-measurement.

Checklist

Reference

GB/T 3811-2008