Stress Concentration at Lightening Hole Edges Causes Fracture of the Lightweight Swing Arm

E42-043 · Insufficient Strength in Lightweight Design · Lightweight Swing Arm · ★★★

Problem Symptom

Cracks appeared at the lightening hole edges and the arm broke

Root Cause

[Hole-Edge Kt] The lightening hole edge has R=1 and Kt=3, giving σ=3×90=270MPa.
[Overload] 270MPa exceeds the allowable [σ]=220MPa, so the hole edge cracked.
[Design Omission] The topology result was not blended with fillets and was not checked, so the arm broke.

Correct Solution

1) Increase the hole edge radius to R≥3;
2) Blend the topology result smoothly;
3) Verify a fatigue life of ≥10 years;
4) Add a thickened edge around the hole;
5) Carry out finite element analysis;
6) Run a bench test;
7) Perform flaw detection;
8) Include hole-edge stress concentration as a constraint in topology optimisation.

Checklist

References

GB/T 19953 Lightweighting