Knowledge Base › Structural Design Error Case Study › Hollow Drive Shaft Thin Wall Causing Torsional Deformation Out of Tolerance

Hollow Drive Shaft Thin Wall Causing Torsional Deformation Out of Tolerance

E42-193 · Insufficient Lightweight Strength · Robot hollow wrist shaft · ★★★

Problem Description

Shaft torsion angle 0.5° (allowable 0.1°), end positioning offset.

Root Cause

[Thin wall] Hollow shaft wall 2mm, polar moment J_p small. [Torsional deformation] Under torque T, torsion angle θ=TL/(GJ_p)=0.5° out of tolerance. [Design Omission] Wall taken small for lightweight, no torsional-stiffness check; positioning offset.

Corrective Solution

1. Increase hollow shaft wall to 4mm.
2. Change to high-modulus material.
3. Shorten span and add supports.
4. FE torsion-angle check.
5. Dynamically balance shaft.
6. Preload against torsional vibration.
7. Optimize stiffness-to-weight ratio.
8. Measured torsion angle.

Checklist

Reference

GB/T 1184-1996