Low Magnesium Alloy Weld Strength Cracking in Lightweight Design

E42-194 · Insufficient Lightweight Strength · Magnesium alloy AZ91 bracket · ★★★

Problem Description

Weld heat-affected zone cracked, load capacity dropped 30%.

Root Cause

[Weak weld] Magnesium alloy hot-crack sensitive, weld strength only 70% of base metal. [Cracking] HAZ microcracks propagated, load capacity dropped 30%. [Design Omission] No friction-stir welding, no preheat; bracket cracked.

Corrective Solution

1. Change to friction-stir welding to reduce hot cracking.
2. Preheat to 150℃ before welding.
3. Use matching filler wire.
4. Add reinforcement plate to weld.
5. Post-weld stress relief.
6. Reduce welding heat input.
7. Weld MT inspection.
8. Load test.

Checklist

Reference

GB/T 5153-2003