Knowledge Base › Structural Design Error Case Study › Welded Frame Insufficient Tempering Post-Weld Deformation

Welded Frame Insufficient Tempering Post-Weld Deformation

E42-493 · Residual Stress Deformation · Welded frame · ★★

Problem Description

Welded frame (2t) insufficient tempering, post-weld deformation 5mm out of tolerance; 2 pieces returned monthly

Root Cause

[Residual stress] No post-weld tempering, residual σ=180MPa released and deformed 5mm.
[Deform] Warpage.
[Design Omission] No aging, no deformation limit; safety factor 1.4 (should be ≥2.0).

Corrective Solution

1) Post-weld temper at 550℃;
2)Vibration stress relief;
3) Pre-set distortion compensation;
4) Segmented welding;
5) Deformation check each piece;
6) Limit welding sequence;
7) Add restraint;
8) Periodic re-measurement.

Checklist

Reference

GB/T 50661-2011