Misalignment of the Pump Set Assembly Causes Coupling Fracture

E42-100 · Other · Centrifugal Pump Set · ★★★

Problem Symptom

Misalignment 0.2mm (allowable 0.05), the coupling fractured

Root Cause

[Misalignment] The two shafts are offset by 0.2mm (allowable 0.05), which adds a parasitic bending moment.
[Fracture] The additional force broke the coupling.
[Design Omission] The shafts were not laser aligned and the alignment was not measured.

Correct Solution

1) Laser align to ≤0.05mm;
2) Add a coupling guard;
3) Level the machine feet;
4) Keep an alignment record;
5) Use a soft start to reduce shock;
6) Re-align periodically;
7) Monitor the bearing condition;
8) Make alignment a mandatory inspection item at installation.

Checklist

References

GB/T 3852-2017 Couplings — Bore and Coupling Types