Wrong Assembly Datum Causes Accumulated Error in the Hole Group

E42-149 · Other · Gearbox Housing Assembly · ★★

Problem Symptom

Locating on the as-cast surface accumulates error and the hole group is 0.06mm out of tolerance

Root Cause

[Wrong Datum] The unmachined as-cast surface is used as the locating datum, so the errors accumulate.
[Out of Tolerance] The accumulation over several operations makes the coaxiality of the hole group 0.06mm out of tolerance.
[Design Omission] The design datum and process datum were not unified, so the error went out of tolerance.

Correct Solution

1) Unify the design, process and inspection datums;
2) Locate on the machined surface;
3) Calculate the datum transfer error;
4) Inspect the coordinates of the critical holes 100%;
5) Design the fixture around the datums;
6) Re-check the first article on a three-coordinate measuring machine;
7) Allocate the accumulated error;
8) Include the datums in the process specification.

Checklist

References

GB/T 1182 Geometrical Product Specifications — Geometrical Tolerances