Insufficient O-Ring Compression Causes Flange Seal Leakage

E42-150 · Other · Hydraulic Station Flange Seal · ★★

Problem Symptom

O-ring compression only 8% (15% required), the joint leaks

Root Cause

[Insufficient Compression] The groove is too deep and the 8% O-ring compression does not reach the sealing threshold, so the contact stress is insufficient.
[Leakage] The medium pressure drives the fluid through the interface.
[Design Omission] The groove was not designed for the compression ratio and the compression was not verified, so the joint leaked.

Correct Solution

1) Redesign the groove for 15% compression;
2) Match the O-ring cord size to the groove;
3) Measure the compression before assembly;
4) Control the roughness of the sealing face;
5) Pressure test and hold to check for leaks;
6) Select the O-ring material according to the medium;
7) Tighten the bolts at an even torque;
8) Include the compression ratio in the seal design.

Checklist

References

GB/T 3452.1 Fluid Power Systems — O-Ring Rubber Seals