E42-199 · Other · Box multi-process machining · ★★
Different surfaces used for positioning, process error 0.05 accumulated out of tolerance.
[Datum mismatch] Different positioning datums per operation, datum mismatch error 0.05. [Accumulation] Multi-operation accumulation out of tolerance. [Design Omission] No unified datum, no error-chain calculation; dimension out.
1. Unify design, process and measurement datums.
2. Calculate datum-transition error.
3. Locate all operations from the same surface.
4. Design fixtures per datum.
5.First-article CMM.
6. Error-chain allocation.
7. Datum incorporated into process specification.
8. Out-of-tolerance dimension analysis.
GB/T 1182-2018