Bolt Hole Position Out of Tolerance Causing Assembly Interference

E42-200 · Other · Flange connection group · ★★

Problem Description

Hole position offset 0.5mm, bolts could not be inserted and required reaming.

Root Cause

[Position out of tolerance] Drill jig worn, hole position offset 0.5mm exceeding position tolerance. [Interference] Bolts hard to insert, forced reaming reduced strength. [Design Omission] No position control ≤0.2, no full gauge inspection; assembly rework.

Corrective Solution

1. Periodic drill-jig replacement against wear.
2. Control position ≤0.2mm.
3. Full gauge inspection of hole position.
4. CNC drill per datum.
5. First-article CMM hole position.
6. Group trial assembly.
7. Weld and re-drill out-of-tolerance holes.
8. Assembly interference analysis.