E42-250 · Other · Box-type part · ★★★
CMM reported 12 out-of-tolerance points, but actual assembly qualified; wrong datum selected.
[Datum misalignment] Drawing datum A wrongly chosen as secondary surface, measurement coordinate system offset. [False reject] Measured against wrong datum offset 0.05mm, falsely judged 12 points as reject. [Design Omission] Datum not main locating face, no M-circle annotation.
1. Change datum to main locating face A.
2. Annotate maximum-material M-circle on datum.
3. Build measurement program per datum.
4. Drawing review confirms datum.
5. First-article CMM re-evaluation.
6. Calibrate gauges per datum.
7. Sampling coordinate-system check per batch.
8. Design-criteria training.
GB/T 1182-2018