E43-104 · Improper Clearance Fit · Mining Gearbox · ★★★
A 0.15mm misalignment of the bearing holes at the split line produced a 0.20mm backlash difference at the gear mesh, so the tooth flank was unevenly loaded, a tooth broke and the machine stopped
[Hole Position Off] After the upper and lower housing halves were closed, the bearing hole coaxiality was 0.15mm out of tolerance, tilting the shafting and shifting the gear pair center distance.
[Uneven Loading] The center distance shift Δa concentrated the tooth flank load on one side; with the contact spot below 30% a tooth broke.
[Design Omission] Locating pins and boring the bearing holes after closing should have been used to keep coaxiality ≤0.03mm, but the split-line assembly process was not controlled.
1) Add two dowel pins on the split face for location;
2) Bore the bearing holes of both halves in one setup;
3) Keep coaxiality ≤0.03mm;
4) Check the contact pattern with blueing compound for ≥70%;
5) Set the backlash to 0.08mm based on the normal module m_n;
6) Provide a loaded run-in;
7) Re-measure the shafting alignment;
8) Inspect incoming housings on a CMM.
GB/T 10095.1-2008 Gear Accuracy