E43-105 · Improper Clearance Fit · Injection Moulding Machine Solenoid Directional Valve · ★★
The clearance between the Φ16 spool and the bore was designed at 0.008mm but measured 0.022mm; internal leakage delayed reversal by 0.4s and slowed the cycle
[Clearance Out of Tolerance] The design called for an H6/h5 clearance of 0.008mm, but the honing allowance on the bore was too large, so the actual clearance reached 0.022mm.
[Internal Leakage] The annular gap leakage Q∝δ³; raising δ from 0.008 to 0.022 increased the leakage about 20 times and the valve lost pressure holding.
[Design Omission] The lapped clearance should have been ≤0.01mm with a leakage test performed, but the lapping process was not controlled.
1) Lap the clearance to ≤0.01mm;
2) Hone the valve bore to Ra0.2;
3) Hard-chrome the spool;
4) Perform a leakage quantity test;
5) Provide pressure difference compensation;
6) Verify from Q∝δ³;
7) Check pressure holding after each reversal;
8) Spot-check every batch.
GB/T 1801-2009 Limits and Fits