E43-106 · Improper Clearance Fit · Air Compressor · ★★
The male/female rotor mesh clearance was designed at 0.10mm but measured 0.35mm; volumetric efficiency fell 12%
[Large Mesh Gap] The design mesh clearance was 0.10mm, but the profile machining allowance was too large and unmeasured, so the actual clearance reached 0.35mm.
[Leakage] The large clearance formed a leakage triangle and high-pressure gas short-circuited to the low-pressure side, cutting volumetric efficiency by 12%.
[Design Omission] The profile machining should have been controlled and the rotors assembled to a 0.12mm clearance, but no leakage triangle calculation was done.
1) Control the mesh clearance to 0.12mm;
2) Finish machine the rotor profiles accurately;
3) Check contact with blueing compound;
4) Perform a gas tightness test;
5) Dynamically balance the rotors;
6) Verify from the leakage triangle;
7) Provide synchronising gears;
8) Inspect the first piece on a CMM.
GB/T 10095.1-2008 Gear Accuracy