Excessive Impeller Wear Ring Clearance in a Centrifugal Pump Cuts Volumetric Efficiency

E43-107 · Improper Clearance Fit · Chemical Process Pump · ★★

Problem Symptom

The clearance between the impeller wear ring and the casing was designed at 0.30mm but measured 0.95mm; volumetric efficiency fell 9%

Root Cause

[Large Wear Ring Gap] The design clearance was 0.30mm, but after the ring wore it opened to 0.95mm and was never replaced.
[Recirculation] The large clearance let high-pressure liquid recirculate through the wear ring back to the inlet, with recirculation Q∝δ cutting volumetric efficiency by 9%.
[Design Omission] A replaceable wear ring should have been provided with the clearance controlled to ≤0.4mm, but no wear replacement interval was defined.

Correct Solution

1) Control the wear ring clearance to ≤0.4mm;
2) Use a replaceable wear ring;
3) Measure the clearance every 8000h;
4) Hard face the wear ring with a wear-resistant layer;
5) Verify with a performance curve;
6) Verify the efficiency from the recirculation Q;
7) Provide balance holes to reduce recirculation;
8) Replace the ring as soon as the wear limit is exceeded.

Checklist

References

GB/T 5656-2008 Centrifugal Pump Technical Conditions