Excessive Coupling Hub Clearance Causes the Key to Be Sheared Off

E43-110 · Improper Clearance Fit · Fan Coupling · ★★

Problem Symptom

The Φ80 coupling hub bore and the shaft were designed with a transition fit but measured 0.12mm clearance; the key was sheared off when torque was transmitted

Root Cause

[Fit Changed to Clearance] An H7/k6 transition fit was designed, but with the bore at the upper limit and the shaft at the lower limit it became a 0.12mm clearance.
[Key Sheared] Torque was carried across the clearance, so the key was put in shear and τ exceeded the limit; the key sheared and the hub slipped.
[Design Omission] A small interference such as H7/n6 with two keys should have been used, but the clearance was left in place and the fit failed.

Correct Solution

1) Change to a small interference H7/n6;
2) Control the bore to the lower limit;
3) Use two keys or a spline;
4) Keep keyway symmetry ≤0.02;
5) Check the torque and τ;
6) Assemble and disassemble hydraulically;
7) Dynamically balance;
8) Spot-check the fit every batch.

Checklist

References

GB/T 1095-2003 Parallel Keys