E43-111 · Improper Clearance Fit · Machining Center Z-Axis · ★★
The ball screw nut clearance was designed at 0.01mm but measured 0.06mm; the reverse dead zone reached 0.08mm and the hole positions differed by 0.05mm
[Large Nut Clearance] The design preload clearance was 0.01mm, but the nut loosened with wear so the actual clearance reached 0.06mm.
[Dead Zone] The clearance produced 0.08mm of reverse free travel, above the 0.01 allowable, so positioning accuracy was lost.
[Design Omission] A double nut preload should have been used to remove the backlash with the reverse gap measured, but the preload force was not controlled.
1) Use double nut preload to remove the backlash;
2) Control the preload force at 30% of rating;
3) Keep reverse backlash ≤0.01mm;
4) Compensate with a laser interferometer;
5) Re-preload the nut periodically;
6) Verify the positioning accuracy against the dead zone;
7) Harden the ball screw;
8) Measure the clearance every batch.
GB/T 17587.3-2018 Ball Screws