Excessive Cam Divider Indexing Clearance Causes Excessive Stop Position Error

E43-112 · Improper Clearance Fit · Turntable Indexing Table · ★★

Problem Symptom

The clearance between the indexing cam and the roller was designed at 0.02mm but measured 0.10mm; the stop position error of 0.15mm displaced the assembled parts

Root Cause

[Large Clearance] The design clearance was 0.02mm, but wear on the roller shaft made the actual clearance 0.10mm.
[Stop Position Error] The clearance caused 0.15mm of indexing overshoot, above the 0.05 allowable, so the indexing accuracy was lost.
[Design Omission] A preload should have been used to remove the clearance with repeatability measured, but no wear compensation was provided.

Correct Solution

1) Provide a preload to remove the clearance;
2) Control the clearance to ≤0.03mm;
3) Harden the roller shaft;
4) Keep repeatability ≤0.05mm;
5) Adjust the preload periodically;
6) Verify the accuracy against the overshoot;
7) Add linear encoder feedback;
8) Spot-check every batch.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances