E43-113 · Improper Clearance Fit · Steam Turbine · ★★
The clearance between the sealing tooth and the rotor was designed at 0.50mm but measured 1.80mm; steam loss cut efficiency by 3%
[Large Seal Clearance] The design clearance was 0.50mm, but after the teeth wore the clearance opened to 1.80mm and the seal was never replaced.
[Steam Loss] The large clearance increased steam loss in proportion to δ, cutting efficiency by 3% and raising the heat rate.
[Design Omission] An adjustable steam seal should have been provided with the clearance controlled to ≤0.60mm, but no replacement interval was defined.
1) Control the steam seal clearance to ≤0.60mm;
2) Use an adjustable steam seal;
3) Measure the clearance at every major repair;
4) Hard face the tooth tips;
5) Verify the efficiency against the steam loss;
6) Provide steam seal leakage monitoring;
7) Inspect rotor runout;
8) Replace as soon as the limit is exceeded.
GB/T 5578-2007 Fixed Steam Turbines