Excessive Plunger-to-Bore Clearance in an Axial Piston Pump Cuts Flow

E43-115 · Improper Clearance Fit · Hydraulic Axial Piston Pump · ★★

Problem Symptom

The clearance between the Φ20 plunger and the bore was designed at 0.01mm but measured 0.035mm; volumetric efficiency fell 10%

Root Cause

[Large Clearance] The design clearance was 0.01mm, but the reaming allowance on the bore was too large, so the actual clearance reached 0.035mm.
[Internal Leakage] With Qleak∝δ³, raising δ from 0.01 to 0.035 increased the leakage about 40 times, cutting the flow.
[Design Omission] The lapped clearance should have been ≤0.012mm with a volumetric efficiency test performed, but the reaming was not controlled.

Correct Solution

1) Lap the clearance to ≤0.012mm;
2) Limit the bore reaming to the upper limit;
3) Hard-chrome the plunger;
4) Perform a volumetric efficiency test;
5) Provide variable displacement compensation;
6) Verify from Qleak∝δ³;
7) Monitor case drain oil;
8) Spot-check every batch.

Checklist

References

GB/T 17446-2012 Hydraulic Pumps