Excessive Clearance Between the Distributor Shaft and the Housing Causes Low-Speed Crawling

E43-126 · Improper Clearance Fit · Travel Hydraulic Motor · ★★

Problem Symptom

The clearance between the Φ40 distributor shaft and the housing was designed at 0.015mm but measured 0.05mm; low-speed stick-slip marks appeared

Root Cause

[Large Clearance] The design clearance was 0.015mm, but wear in the housing bore made the actual clearance 0.05mm.
[Crawling] The large clearance caused internal leakage, so the torque fluctuated at low speed and the motor crawled.
[Design Omission] The clearance should have been lapped to ≤0.02mm with a low-speed test performed, but bore wear was not controlled.

Correct Solution

1) Lap the clearance to ≤0.02mm;
2) Hone the housing bore;
3) Carry out a low-speed crawling test;
4) Hard-chrome the shaft;
5) Verify the torque against the leakage;
6) Provide a makeup oil valve;
7) Change the oil regularly;
8) Spot-check every batch.