Excessive Gear Tip-to-Bore Clearance in a Gear Pump Causes Internal Leakage

E43-127 · Improper Clearance Fit · Lubricating Oil Pump · ★

Problem Symptom

The clearance between the gear tip and the pump body was designed at 0.03mm but measured 0.12mm; volumetric efficiency fell 8%

Root Cause

[Large Tip Clearance] The design clearance was 0.03mm, but wear opened up the pump body bore so the actual clearance reached 0.12mm.
[Internal Leakage] With the large clearance, high-pressure oil leaked past the gear tips and efficiency fell 8%.
[Design Omission] The clearance should have been controlled to ≤0.04mm with a floating side plate provided, but wear was not controlled.

Correct Solution

1) Control the clearance to ≤0.04mm;
2) Hard face the pump body bore;
3) Use a floating side plate to compensate the gap;
4) Perform a volumetric efficiency test;
5) Verify the efficiency against the leakage;
6) Inspect the gear tip circle;
7) Replace parts regularly;
8) Spot-check every batch.

Checklist

References

GB/T 1801-2009 Limits and Fits