Excessive Scroll Plate Clearance in a Scroll Compressor Cuts Efficiency

E43-129 · Improper Clearance Fit · Refrigeration Scroll Compressor · ★★

Problem Symptom

The mesh clearance between the fixed and orbiting plates was designed at 0.02mm but measured 0.08mm; volumetric efficiency fell 7%

Root Cause

[Large Plate Gap] The design clearance was 0.02mm, but wear of the orbiting plate made the actual clearance 0.08mm.
[Leakage] The large clearance formed a leakage path and efficiency fell 7%.
[Design Omission] The clearance should have been controlled to ≤0.03mm with axial float provided, but wear was not controlled.

Correct Solution

1) Control the clearance to ≤0.03mm;
2) Give the orbiting plate axial float to compensate;
3) Grind the plate end faces;
4) Perform a volumetric efficiency test;
5) Verify the efficiency against the leakage;
6) Use an oil film seal;
7) Replace the plates regularly;
8) Spot-check every batch.