E43-130 · Improper Clearance Fit · Construction Machinery Hydraulic Cylinder · ★★
The clearance between the Φ63 piston rod and the guide bushing was designed at 0.05mm but measured 0.20mm; oil leaked externally
[Large Clearance] The design clearance was 0.05mm, but corrosion opened up the guide bushing bore so the actual clearance reached 0.20mm.
[External Leakage] With the large clearance the wiper seal failed and oil escaped, contaminating the environment.
[Design Omission] The bushing should have been chromed with the clearance controlled to ≤0.06mm and dual seals provided, but corrosion was not controlled.
1) Control the clearance to ≤0.06mm;
2) Chrome the guide bushing bore;
3) Fit dual wiper seals;
4) Harden the piston rod to Ra0.2;
5) Carry out an external leakage check;
6) Verify the seal against the clearance;
7) Replace the seals regularly;
8) Spot-check every batch.
GB/T 1801-2009 Limits and Fits