E43-136 · Improper Clearance Fit · Fan Pulley · ★
The Φ40 pulley bore and the shaft were designed with a transition fit but measured 0.08mm clearance; the V-belt slipped and lost 12% of speed
[Fit Changed to Clearance] The H7/k6 transition fit became a 0.08mm clearance.
[Slipping] With the large clearance friction alone could not transmit the torque, so the belt slipped and lost 12% of speed.
[Design Omission] H7/m6 with a key should have been used, but the clearance was left in place.
1) Change to H7/m6;
2) Control the bore to the lower limit;
3) Add a parallel key to transmit circumferential torque;
4) Verify the tensioning force;
5) Verify the transmission against the slip;
6) Dynamically balance;
7) Re-tighten regularly;
8) Spot-check every batch.
GB/T 1095-2003 Parallel Keys