Excessive Flange Sealing Face Clearance Causes External Leakage

E43-137 · Improper Clearance Fit · Pipe Flange · ★

Problem Symptom

The clearance between the flange sealing face and the gasket was designed at 0.10mm but measured 0.40mm; the medium leaked externally

Root Cause

[Large Clearance] The design compression gap was 0.10mm, but the bolts loosened so the actual gap reached 0.40mm.
[External Leakage] With the large gap the gasket could not be compressed and the medium escaped.
[Design Omission] The bolt torque should have been controlled to keep the gap ≤0.12mm, but the preload was not controlled.

Correct Solution

1) Control the compression gap to ≤0.12mm;
2) Calibrate the bolt torque;
3) Select a matching gasket;
4) Perform a gas tightness test;
5) Verify the compression against the force;
6) Check the tightening periodically;
7) Keep the flange face flat;
8) Inspect the torque on every batch.